Access Alarm Configuration
1.Alarm detection mode
1.1 close: The alarm is in the off state, no alarm state output and action.
1.2 Low level alarm: When the alarm input status changes from high level to low level, it will trigger the alarm (57V >high level >5V, low level < 5V)
1.3 High level alarm: When the alarm input status changes from low level to high level, it will trigger the alarm (57V >high level >5V, low level < 5V)
1.4 Upload fault Message: select here then will show alarm input status in switch log
2. Close port
2.1 Select port: Select the port which needs to do action after the alarm is triggered. The action will be close the selected port. After the alarm is canceled, the action will resume open the selected port. the alarm is triggered-canceled one time, the selected port will restart(close-open) one time
2.2 Status box: alarm/normal
3. Reboot port
3.1 Select port: Select the port which needs to do action after the alarm is triggered. The action will be reboot the selected port. the alarm is triggered one time, the selected port will reboot one time
3.2 Status box: alarm/normal
Alarm Output Configuration
1. Alarm output mode
1.1 Close: The alarm output is in the closed state, and there is no alarm output and action.
1.2 Alarm (often close) : When the alarm is triggered, the alarm output closed-circuit
1.3 Alarm (often open) : When the alarm is triggered, the alarm output open-circuit
1.4 Alarm Impulse : when the alarm is triggered, the alarm output open/closed circuit cyclic
1.5 Upload fault Message: select here then will show alarm output status in switch log
2. Port status monitoring
2.1 Select port
2.11 Data port monitoring: Monitoring the selected data port status. When the status is abnormal, alarm output will be triggered. When the status is normal, alarm will be canceled. For select data port, you can select ge1/1 to ge 1/12.
2.12 PoE port monitoring: Monitoring the selected PoE port status. When the status is abnormal, alarm output will be triggered. When the status is normal, alarm will be canceled. For select data port, you can select ge1/1P to ge 1/8P.
3. Executive action
3.1 Status: alarm port display
System Condition Failure
4.1 System temperature: mean the temperature of Switch itself. Set a temperature value range if beyond this range to trigger an alarm
4.2 Ambient temperature: Set a temperature value range if beyond this range to trigger an alarm, which requires an external sensor (included in product packing box)
4.3 Ambient humidity: Set a humidity value range if beyond this range to trigger an alarm, which requires an external sensor (included in product packing box)
4.4 System power overload: Set a power consumption value range if beyond this range to trigger an alarm
4.5 Master V1 voltage: Trigger alarm is judged by monitoring power V1 input status
4.6 Slave V2 voltage: Trigger alarm is judged by monitoring power V2 input status
4.7 System 3.3V: Trigger alarm is judged by monitoring switch board 3.3V voltage status
4.8 System 1.5V: Trigger alarm is judged by monitoring switch board 1.5V voltage status
4.9 System 1.2V: Trigger alarm is judged by monitoring switch board 1.2V voltage status
4.10 Alarm input: The alarm is triggered by the effective status of the alarm input detection, and the alarm input function needs to be enabled
5.Executive action
5.1 Status: alarm port display